Xpeed SDSL Interface
| Document revision: | 1.2 (February 6, 2008, 2:56 GMT) |
| Applies to: | V3.0 |
General Information
Summary
The MikroTik RouterOS supports the Xpeed 300 SDSL PCI Adapter hardware with speeds up to 2.32Mbps. This device can operate either using Frame Relay or PPP type of connection. SDSL (Single-line Digital Subscriber Line or Symmetric Digital Subscriber Line) stands for the type of DSL that uses only one of the two cable pairs for transmission. SDSL allows residential or small office users to share the same telephone for data transmission and voice or fax telephony.
Specifications
Packages required: synchronousLicense required: Level4
Submenu level: /interface xpeed
Standards and Technologies: PPP (RFC 1661), Frame Relay (RFC 1490)
Hardware usage: Not significant
Additional Resources
Xpeed Interface Configuration
Submenu level: /interface xpeedProperty Description
arp (disabled | enabled | proxy-arp | reply-only; default: enabled) - Address Resolution Protocolenabled - the interface will use ARP protocol
proxy-arp - the interface will be an ARP proxy
reply-only - the interface will only reply to the requests originated to its own IP addresses, but neighbor MAC addresses will be gathered from /ip arp statically set table only
line-termination - LMI will operate in LT (Line Termination) mode
network-termination - LMI will operate in NT (Network Termination) mode
network-termination-bidirectional - LMI will operate in bidirectional NT mode
Example
To enable interface:
[admin@r1] interface> print Flags: X - disabled, R - running, D - dynamic, S - slave # NAME TYPE MTU 0 R outer ether 1500 1 R inner ether 1500 2 X xpeed1 xpeed 1500 [admin@r1] interface> enable 2 [admin@r1] interface> print Flags: X - disabled, R - running, D - dynamic, S - slave # NAME TYPE MTU 0 R outer ether 1500 1 R inner ether 1500 2 R xpeed1 xpeed 1500 [admin@r1] interface>
Frame Relay Configuration Examples
MikroTik Router to MikroTik Router
Consider the following network setup with MikroTik router connected via SDSL line using Xpeed interface to another MikroTik router with Xpeed 300 SDSL adapter. SDSL line can refer a common patch cable included with the Xpeed 300 SDSL adapter (such a connection is called Back-to-Back). Lets name the first router r1 and the second r2.
Router r1 setup
The following setup is identical to one in the first example:
[admin@r1] ip address> add inter=xpeed1 address 1.1.1.1/24
[admin@r1] ip address> print
Flags: X - disabled, I - invalid, D - dynamic
# ADDRESS NETWORK BROADCAST INTERFACE
0 1.1.1.1/24 1.1.1.0 1.1.1.255 xpeed1
[admin@r1] interface xpeed> print
Flags: X - disabled
0 name="xpeed1" mtu=1500 mac-address=00:05:7A:00:00:08 arp=enabled
mode=network-termination sdsl-speed=2320 sdsl-invert=no sdsl-swap=no
bridged-ethernet=yes dlci=16 lmi-mode=off cr=0
[admin@r1] interface xpeed>
Router r2 setup
First, we need to add a suitable IP address:
[admin@r2] ip address> add inter=xpeed1 address 1.1.1.2/24 [admin@r2] ip address> pri Flags: X - disabled, I - invalid, D - dynamic # ADDRESS NETWORK BROADCAST INTERFACE 0 1.1.1.2/24 1.1.1.0 1.1.1.255 xpeed1
Then, some changes in xpeed interface configuration should be done:
[admin@r2] interface xpeed> print
Flags: X - disabled
0 name="xpeed1" mtu=1500 mac-address=00:05:7A:00:00:08 arp=enabled
mode=network-termination sdsl-speed=2320 sdsl-invert=no sdsl-swap=no
bridged-ethernet=yes dlci=16 lmi-mode=off cr=0
[admin@r2] interface xpeed> set 0 mode=line-termination
[admin@r2] interface xpeed>
Now r1 and r2 can ping each other.
MikroTik Router to Cisco Router
Let us consider the following network setup with MikroTik Router with Xpeed interface connected to a leased line with a CISCO router at the other end.
MikroTik router setup:
[admin@r1] ip address> add inter=xpeed1 address 1.1.1.1/24
[admin@r1] ip address> print
Flags: X - disabled, I - invalid, D - dynamic
# ADDRESS NETWORK BROADCAST INTERFACE
0 1.1.1.1/24 1.1.1.0 1.1.1.255 xpeed1
[admin@r1] interface xpeed> print
Flags: X - disabled
0 name="xpeed1" mtu=1500 mac-address=00:05:7A:00:00:08 arp=enabled
mode=network-termination sdsl-speed=2320 sdsl-invert=no sdsl-swap=no
bridged-ethernet=yes dlci=42 lmi-mode=off cr=0
[admin@r1] interface xpeed>
Cisco router setup
CISCO# show running-config Building configuration... Current configuration... ... ! ip subnet-zero no ip domain-lookup frame-relay switching ! interface Ethernet0 description connected to EthernetLAN ip address 10.0.0.254 255.255.255.0 ! interface Serial0 description connected to Internet no ip address encapsulation frame-relay IETF serial restart-delay 1 frame-relay lmi-type ansi frame-relay intf-type dce ! interface Serial0.1 point-to-point ip address 1.1.1.2 255.255.255.0 no arp frame-relay frame-relay interface-dlci 42 ! ... end. Send ping to MikroTik router CISCO#ping 1.1.1.1 Type escape sequence to abort. Sending 5, 100-byte ICMP Echos to 1.1.1.1, timeout is 2 seconds: !!!!! Success rate is 100 percent (5/5), round-trip min/avg/max = 28/31/32 ms CISCO#
Troubleshooting
Description
-
I tried to connect two routers as shown in MT-to-MT, but nothing happens
The link indicators on both cards must be on. If it's not, check the cable or interface configuration. One adapter should use LT mode and the other NT mode. You can also change sdsl-swap and sdsl-invert parameters on the router running LT mode if you have a very long line